LC3000-PCD post-column derivatization analysis system

LC3000-PCD post-column derivatization analysis system

Key words:

Classification:

Pesticide residue detector

Product Consulting:

  • Product Description
  • Technical parameters
  • More introduction
    • Commodity name: LC3000-PCD post-column derivatization analysis system
    • Commodity ID: 1091282567928893440

    Equipment Introduction

    LC3000-PCDpost-column derivative analysis system, Continue the advantages of the previous generation of derivative systems, and increase the communication network port connection, so that the workstation has an additional choice when communicating. mainlyP3000NType high-pressure infusion pump, Shimadzu fluorescence detector, post-column derivative pump.

    The excellent pump drive system makes the pump have better performance, higher accuracy and better stability. The high-efficiency electronic pulsation suppression technology is used to reduce the pulsation to a minimum. This allows the system to meet the needs of most advanced users. The dual pump system can achieve both gradient conditions and perform isocratic work, giving the operator more options.

    Firmware program all use remote online update, the operation is more convenient, the function icon display, the operation of high recognition.

     

    Equipment features

    Multi-point correction, more stable performance, more accurate parameters;

    The gradient is easy to adjust;

    Modular units are easy to combine;

    Positive and negative switching freely;

    Bioanalytical compatible systems are available;

    Modular design;

    Single or double reaction core can be selected, and the two-step reaction process of heating reaction and normal temperature reaction can be carried out at the same time;

    Optional1Taiwan,2one or more derivative pumps;

    Panel display, easy to set up;

    The front panel of the reactor displays the set temperature and actual temperature of each reaction core;

    The front panel of the derivatization pump displays the flow rate, pressure, and pressure limit for each reagent.

     

    Application areas

    Pharmaceutical industry

    Food Industry

    Chemical Industry

    environmental protection industry

    veterinary drug feed

     

  • Technical Parameters

    P3000N High Pressure Infusion Pump

    Flow range:

    (0 000110)mL/min

    Maximum working pressure:

    42MPa

    Flow accuracy:

    ±0.5%(1mL/min)

    Flow repeatability:

    RSD≤0.5%

    Pressure pulsation:

    Pressure pulsation ≤ 1.5% , @10Mpa

    Gradient error:

    ±2%

    power supply:

    110V-220V 50Hz-60Hz, 100W

    Dimensions and weight:

    455×265×190mm ( × W × H ) 12.8kg

     

    Post-column derivatizer (built-in pump)

    Flow range:

    (0 000110)mL/min

    Maximum working pressure:

    42MPa

    Flow accuracy:

    ±0.5%(1mL/min)

    Flow repeatability:

    RSD≤0.5%

    Pressure pulsation:

    Pressure pulsation ≤ 2% , @10Mpa

    Temperature control accuracy:

    ±0.5%FS ± 2Digit

    Measuring range:

    -99 999

    Temperature control alarm range:

    Full scale free setting

    Display method:

    LCD

    Reaction tube:

    Adjust according to application

    power supply:

    110V-220V 50Hz-60Hz, 100W

    Dimensions and weight:

    455×265×190mm ( × W × H ) 14kg

     

    System configuration (recommended)

    serial number

    product name

    quantity

    1

    P3000N High Pressure Infusion Pump

    units (gradient)

    2

    Post-column derivatizer (built-in pump)

    sets (hydrolysis pump + derivative pump)

    3

    Fluorescence detector

    unit

    4

    Analytical Solvent Tissue Cassettes

    unit

    5

    10ul quantitative loop

    (other models are optional)

    6

    German Analytical Dynamic Mixer

    set

    7

    dual channel workstation

    set

    8

    Workstation (with dongle)

    set (standard configuration)

    9

    Analytical Binary Toolkit

    set

    10

    Post-column Derivative System Kit

    set

    11

    Column oven

    unit

    Note: The specific system configuration composition also needs to refer to customer needs, increase or decrease accessories, etc. The above configuration is only for reference

     

  • Commonly used consumables(Optional)

    1)  Analysis of high pressure seal ring

    2)  Low pressure sealing ring for analysis

    3)  Analyze the finished plunger3.175 × 42

    4)  Analysis pump check valve